| Thermal Insulation | Panel core thickness, declared thermal conductivity, joints, and thermal bridging at fixings. | PU core thermal conductivity is commonly about 0.022–0.028 W/m·K. Typical thicknesses range from 40–150 mm. | Thicker panels generally reduce heat transfer and operating costs but increase material and handling costs. | Select thickness according to the required indoor temperature, local climate, building use, and applicable energy code rather than choosing by price alone. |
| Fire Performance | Reaction-to-fire classification, fire-resistance rating of the complete wall or roof assembly, joint design, and test documentation. | Fire performance varies significantly by facing material, core formulation, thickness, joints, and installation details. Ratings must be confirmed for the complete assembly. | High impact: inadequate fire performance can create serious life-safety, approval, insurance, and replacement risks. | Request current third-party test reports and select panels that meet the project’s required fire classification and compartmentation strategy. |
| Moisture and Vapor Control | Panel joint seals, vapor-barrier continuity, condensation risk, water drainage, and compatibility with the interior environment. | Cold rooms, food-processing areas, and humid spaces usually require carefully sealed joints and hygienic, washable surfaces. | Poor detailing can cause condensation, corrosion, mold growth, insulation loss, and premature panel replacement. | Use compatible gaskets or sealants, maintain continuous vapor control, and detail penetrations before installation begins. |
| Structural and Wind Loads | Panel span, support spacing, wind pressure or suction, snow load for roofs, fastener capacity, and deflection limits. | Allowable spans vary by panel thickness, profile, facing steel thickness, support conditions, and design load. Do not rely on a generic span value. | High impact: undersized panels or fasteners may lead to excessive deflection, leakage, or structural failure. | Use project-specific load calculations and manufacturer-tested span tables. Verify both positive and negative wind pressure. |
| Facing Material and Coating | Steel thickness, corrosion protection, coating type, surface finish, chemical exposure, and cleaning requirements. | Common steel facings are approximately 0.40–0.80 mm thick. More aggressive environments may require enhanced corrosion protection. | Higher-grade facings can increase initial cost but improve durability in humid, coastal, chemical, or wash-down environments. | Match the coating and facing thickness to exposure conditions. Avoid selecting a finish based only on appearance or lowest purchase price. |
| Panel Dimensions and Joint Design | Panel length, width, joint profile, tongue-and-groove fit, cam locks if applicable, tolerances, and corner details. | Longer panels reduce the number of horizontal joints but may require additional lifting equipment and careful transport planning. | Fewer joints can reduce leakage and installation labor; oversized panels may increase handling damage and site risk. | Optimize panel sizes for transport routes, lifting capacity, building geometry, and the number of penetrations or openings. |
| Installation Labor | Crew skill, installation sequence, cutting method, lifting equipment, access conditions, and weather limitations. | Installation productivity depends on panel size, site access, detailing complexity, and the number of openings. Labor rates vary by region and project conditions. | Poor planning increases installation time, offcuts, sealant use, damage, and rework costs. | Prepare shop drawings, panel schedules, lifting plans, and a joint-sealing procedure before materials arrive on site. |
| Worker Safety | Manual handling weight, sharp edges, work-at-height controls, temporary bracing, lifting points, and personal protective equipment. | Panels should be handled by a suitably sized crew or mechanical equipment according to panel length and weight. Roof work requires fall protection. | High impact: uncontrolled lifting, unstable panels, and unprotected roof edges can cause severe injuries. | Use a site-specific risk assessment, exclusion zones, edge protection, fall-arrest systems where required, gloves, eye protection, and safe lifting procedures. |
| Fasteners and Accessories | Fastener type, length, corrosion resistance, washer size, spacing, flashings, trims, closures, and sealants. | Fastener selection depends on substrate, panel thickness, design loads, and environmental exposure. Accessories can represent a significant portion of installed cost. | Incorrect fasteners or missing closures can cause pull-out, corrosion, water ingress, and loss of air tightness. | Specify a complete compatible system, including fasteners and flashings. Do not mix accessories without checking chemical and dimensional compatibility. |
| Air Tightness and Energy Use | Joint compression, seal continuity, door interfaces, service penetrations, and roof-to-wall transitions. | Air leakage is often controlled more by workmanship and detailing than by the nominal insulation value of the panel. | Leaks increase heating or cooling demand and may cause condensation at cold surfaces. | Include an installation inspection checklist and, where appropriate, conduct visual checks or air-leakage testing before closing concealed areas. |
| Hygiene and Cleanability | Surface smoothness, joint profile, resistance to detergents, impact resistance, and compatibility with sanitation procedures. | Food, pharmaceutical, and medical areas generally require sealed, non-porous, easy-to-clean surfaces and carefully finished corners. | Unsuitable surfaces can increase maintenance costs and create contamination-control difficulties. | Choose finishes and joint details that tolerate the planned cleaning chemicals, temperature, pressure, and frequency of wash-down. |
| Life-Cycle Cost | Purchase price, accessories, installation labor, energy use, maintenance, repairability, service life, and disposal. | The lowest panel price may not be the lowest installed cost because labor, trims, fasteners, access equipment, and sealing materials can materially affect the total. | A higher-performing system may reduce energy, maintenance, and replacement costs over the building’s service life. | Compare at least three scenarios using total installed cost and expected operating performance, not panel price alone. |
| Lead Time and Availability | Production schedule, standard versus custom dimensions, accessory availability, delivery sequence, and storage requirements. | Custom colors, unusual lengths, special coatings, and non-standard thicknesses may require longer procurement periods. | Late delivery can delay the building enclosure and increase labor, storage, and temporary-weather-protection costs. | Approve shop drawings early, confirm all accessories at the same time, and coordinate deliveries with the installation sequence. |
| Quality Control and Documentation | Product data sheets, installation instructions, batch records, test reports, tolerances, delivery inspection, and warranty conditions. | Documentation should identify core type, thickness, facing specification, fire data, thermal data, and applicable standards or test methods. | Complete records simplify approvals, inspections, maintenance, and future repairs. | Inspect panels for dents, wet packaging, damaged edges, coating defects, and dimensional problems before installation and record nonconformities. |